We continue to innovate by introducing the 2018 line of ZFS high-performance storage. Built by senior engineers and tested in a heavy traffic production environment. Powered by Oracle Solaris 11.3, the world’s most advanced enterprise operating system, engineered for large scaled deployments and for mission critical applications that have built in the latest version of the blazing fast and self healing ZFS filesystem. Running on Supermicro latest hardware SuperStorage Server platform, validated by the Supermicro Engineering team, these servers are ready for M&E high performance demanding workflows. We can deliver line rate  on PC workstation using 100GbE Chelsio NIC and 1GB/sec to a MacPro using 10GbE NIC.

Our servers are supported up by the Supermicro THREE YEARS manufacturer warranty and ONE YEAR Oracle Solaris Premier Subscription support.

 

 

zfsf100ZFS-F100

Ultra High Perfomance Flash Storage 5,663,100 read IOPS in 2U chassis, 96TB raw flash storage 

Perfomance:

  • 27 GB/sec of bandwidth at the Volume level tested with fio-2.1.7 on CentOS Linux Server v7.0
  • 4.7 GB/sec Networking speed tested with CLI tool iperf 10 threads. Higher network perfomace is also achieved with NFS over RDMA using Chelsio hardware see white paper..

Integration:

  • 100G, 40G Ethernet QSFP, IB, 10G Ethernet SFP+ and RJ45. Higher network performace is also achieved with NFS over RDMA using Chelsio hardware see white paper..
  • NFS v2/v3/v4, SMB1/2/3, HTTP, WebDAV, FTP/SFTP/FTPS

    Full data sheet availble >> 

     

    • ZFS-600

      ZFS-600 high performance 24GB/sec tested with iozone multithreaded

      ZFS-600 High performance server

      High Performance  Storage 32GB/sec  in 4U chassis, 600TB raw 

      Perfomance:

      • New generation Skylake CPU,  10TB HGST He10 drives and DDR4 ECC RDIMM RAM
      • 197 GB/sec sustained memory bandwidth
      • 32 GB/sec of bandwidth at the Volume level tested with CLI tool multithreated iozone
      • 4.7 GB/sec Networking speed tested with CLI tools iperf 10 threads
      • NVME drives for read/write cache

       

      Integration:

      • 100Gb, 40Gb Ethernet QSFP, IB, 10G Ethernet SFP+ and RJ45. Higher network performace is also achieved with NFS over RDMA using Chelsio hardware see white paper..
      • NFS v2/v3/v4, SMB1/2/3, AFP, HTTP, WebDAV, FTP/SFTP/FTPS

      Read full System Benchmarks >> 

       

    ZFS-500zfs500

    High Performance  Storage 7GB/sec  in 4U chassis, 576TB raw 

    Perfomance:

    • 7 GB/sec of bandwidth at the Volume level tested with CLI tool dd
    • 4.7 GB/sec Networking speed tested with CLI tools iperf 10 threads

     

    Integration:

    • 100G, 40G Ethernet QSFP, IB, 10G Ethernet SFP+ and RJ45. Higher network performace is also achieved with NFS over RDMA using Chelsio hardware see white paper..
    • NFS v2/v3/v4, SMB1/2/3, AFP, HTTP, WebDAV, FTP/SFTP/FTPS

    Full data sheet availble >> 

     

 

ZFS-300

High Performance  Storage 7GB/sec  in 4U chassis, 288TB raw, Multipathing enabled    

Perfomance:

  • 7 GB/sec of bandwidth at the Volume level tested with CLI tool dd
  • 4.7 GB/sec Networking speed tested with CLI tools iperf 10 threads. Higher network performace is also achieved with NFS over RDMA using Chelsio hardware see white paper..

Integration:

  • 100G, 40G Ethernet QSFP, IB, 10G Ethernet SFP+ and RJ45
  • NFS v2/v3/v4, SMB1/2/3, AFP, HTTP, WebDAV, FTP/SFTP/FTPS

Full data sheet availble >> 

 

ZFS-200

High Performance  Storage 6GB/sec  in 4U chassis, 192TB raw, Multipathing enabled

Ideal for less than 10 edit bays or 10 GFX workstations    

Perfomance:

  • 6 GB/sec of bandwidth at the Volume level tested with CLI tool dd
  • 2.4 GB/sec Networking speed tested with CLI tools iperf 10 threads. Higher network performace is also achieved with NFS over RDMA using Chelsio hardware see white paper..

Integration:

  • 40G Ethernet QSFP, IB, 10G Ethernet SFP+ and RJ45
  • NFS v2/v3/v4, SMB1/2/3, AFP, HTTP, WebDAV, FTP/SFTP/FTPS

Full data sheet availble >>